您好,欢迎来到南京医科大学专业采购服务平台(建设单位:喀斯玛商城)
请登录 [ 会员 ]

入驻第

一步法人白介素6(IL6)酶联免疫吸附检测试剂盒



商城价:¥1960.00 市场价:¥2800.00


货号:ELK001ES

规格:
  • 96T

品牌:ELK Biotechnology (一级代理)

计量单位:盒

交货周期:4

库存:999

运杂费: 登录后可查看运杂费

  • 产品详情
  • 包装清单
  • 售后服务

Overview

Product name: EasyStep Human IL6(Interleukin 6) ELISA Kit
Reactivity: Human
Alternative Names: IL-6;MGI2-A; MGI2A; HGF; BSF2; HSF; IFNB2; B-Cell Stimulatory Factor-2; Hybridoma/Plasmacytoma Growth Factor; Hepatocyte Stimulating Factor; Cytotoxic T-Cell Differentiation Factor
Assay Type: Sandwich
Sensitivity: 0.1 pg/mL
Standard: 100 pg/mL
Detection Range: 1.56-100 pg/mL
Sample Type: serum, plasma
Assay Length: 1.5 h
Research Area: Cytokine;Tumor immunity;Infection immunity;Cardiovascular biology;
Uniprot ID: P05231
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IL6, and the Human IL6 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human IL6. After TMB substrate solution is added, only those wells that contain Human IL6 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IL6 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
100.00 2.999 2.939
50.00 2.373 2.313
25.00 1.683 1.623
12.50 1.117 1.057
6.25 0.708 0.648
3.13 0.344 0.284
1.57 0.175 0.115
0.00 0.060 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IL6 and the recovery rates were calculated by comparing the measured value to the expected amount of IL6 in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 95-110% 100%
Heparin plasma(n=5) 93-102% 98%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-98% 98-110% 99-116% 95-110%
EDTA plasma(n=5) 87-102% 85-95% 85-98% 82-95%
Heparin plasma(n=5) 88-102% 95-106% 95-108% 96-115%
  • 版权所有:南京医科大学
  • 传真:025-86508960
  • 线下商家登录
  • 地址:南京市江宁区龙眠大道101号邮编:211166
  • 系统支持:喀斯玛(北京)科技有限公司